Infrared Carbon Monoxide Analyzer

Infrared carbon monoxide analyzer is designed based on the principle that the gas has a selective absorption of infrared light. It has the characteristics of small size, fast response, high accuracy and easy to carry. It can continuously measure the concentration of CO gas in indoor and outdoor ambi
Products Inquiry

Product Details

Infrared carbon monoxide analyzer is designed based on the principle that the gas has a selective absorption of infrared light. It has the characteristics of small size, fast response, high accuracy and easy to carry. It can continuously measure the concentration of CO gas in indoor and outdoor ambient air.
Infrared carbon monoxide analyzer main features:
1. Friendly communication menu makes the operation visual and simple;
2. Long calibration interval cycle, high accuracy and reliable stability;
3.It is of good selectivity to the tested gas;
4.The imported electrochemistry sensor is with relatively rare error, a rapid response speed,  high accuracy and long calibration cycle for features; 
5.The compensation system for temperature can eliminate the influence from environment temperature;
6.With the standard RS232(default)or RS485 communication port carried by it,the analyzer can do bidirectional communication with the computer;


Infrared carbon monoxide analyzer technical parameters:
 Test principle Infrared principle
 Display mode 128×64 matrix dot LCD
 Test range 0 ~ 1000ppm/10.00% CO
 Accuracy ≤±1.2%FS
 Repeatability ≤±1%
 Error <±1.2%FS
 Response time T90≤60S
 Analog output

4-20mA.DC(non-isolated output, loaded resistance lower than 500 Ohm).

 0-10V.DC(non-isolated output, loaded resistance higher than 10k Ohm).

1 way programmable alarm output (Dry contact type, maximum load 220VAC/2A)  .

 Communication port RS232(default)or RS485
 Power supply AC170 ~   264V  50/60Hz
 Environment temperature -10℃ ~ +40℃
 Environment humidity <80%RH
 Sampling mode sample gas   pass-in
 Sample gas temperature 0 ~ 50℃
 Sample gas flow 400 ~   800ml/min
 Sample gas pressure 0.05Mpa≤entrance displayed pressure≤0.35Mpa,steady pressure environment
 Appearance Size 133mm×268mm×300mm(H×W×D)
 Install Hole Cut 135mm×228mm(H×W)
 Serving life >24   months (under normal use)
 Gas circuit port NPT 1/8 internal thread
 Install mode frame mount
Disclaimer: The product introduction content (including product images, product descriptions, technical parameters, etc.) of this site is for reference only. As the update may not be timely, there will be some differences between the content and the actual situation. Please contact our sales staff to confirm. The information provided on this site does not constitute any offer or promise, and the company will improve or modify any information on the website from time to time without prior notice.